VALLEYLAB™ LS10 GENERATOR
VALLEYLAB™ LS10 GENERATOR
Single-channel LigaSure™ generator
The Valleylab™ LS10 electrosurgical generator is a portable unit that made LigaSure™ vessel sealing technology accessible to customers around the globe.
Features
Features of the LS10 vessel sealing generator include:
- TissueFect™ sensing technology across all modalities
- LigaSure™ fusion technology for vessel sealing
- On-site updates via the Valleylab™ exchange software update system
Specialties using the Valleylab™ LS10 generator include:
- Colorectal
- Urology
- General surgery
- Plastics
- Gynecology
Specifications
General characteristics
Output configuration | Isolated output |
---|---|
Cooling | Natural and forced convection |
Display | System status indicator — circle LED (12 blocks) shows system status |
System error indicator — triangle LED with exclamation mark | |
Instrument status indicator — LED above the LigaSure™ receptacle | |
Usage limit indicator — two with a line through it | |
Mounting | A Medtronic cart (UC8009) or a stable, flat surface |
Dimensions and weight
Width | 300 mm (11.81 in) |
---|---|
Depth | 377 mm (14.84 in) |
Height | 105 mm (4.13 in) |
Weight | 5 kg (11 lbs) |
Ligasure™ output characteristics
P–P voltage | Rated load (Ohms) | Maximum power (watts) | Duty cycle |
---|---|---|---|
500 V | 30 | 270 | N/A |
Input power
100–120 Volt | 220–240 Volt |
---|---|
|
|
Product features
Product features
Made in highest quality, surgical grade stainless steel with satin finish to reduce glare. The instrument can be sterilized and reused.
Materials and care
Materials and care
PRODUCTS
This reprocessing instruction applies to reusable surgical and endoscopic instruments supplied by MEDLENE Medical.
GENERAL
Reusable surgical instruments from MEDLENE Medical can be used by medical professionals for a surgical procedure and can be reused after qualified reprocessing.
The professional user selects the appropriate instruments according to the intended function, the tissue to be manipulated and the anatomical structures.
WARNINGS AND PRECAUTIONS
MEDLENE Medical instruments must be cleaned, disinfected,
and sterilized before first use. Protective caps and transport packaging must be
removed beforehand.
A complete functional check must be carried out before each use. Improper use and overstraining due to twisting / levering can lead to breaks and permanent deformation.
Do not use metal brushes or abrasives, as there is a risk of corrosion due to surface damage. The safe
combination of instruments with each other or of instruments with implants must be checked by the user before clinical use.
Be careful when handling sharp tips and cutting edges - risk of injury.
In case of patients with Creutzfeldt-Jakob disease (CJK), suspected CJK or possible variants of this disease, the applicable national regulations regarding the preparation of instruments must be applied. Never leave instruments in disinfectant solution for too long. Follow the instructions of the respective manufacturer.
Share



Excellent Delivery Time.
Exact Product As Per Requirement.