ARLT LENS SCOOP SERRATED 13,0 CM
ARLT LENS SCOOP SERRATED 13,0 CM
Medlene® Keener-Arlt Lens Loop is a specialized surgical instrument that ophthalmic surgeons commonly use to carry out the extraction of the lens nucleus from the capsular bag, especially during phaco and other cataract procedures.
- Atraumatic Wire Loop Tip For Avoiding Local Injury.
- Slightly Curved Working End For Embracing Nuclei With Ease.
- Ergonomic Solid Handle For Superior Control.
The Keener-Arlt Lens Loop brings multiple benefits to the ophthalmic surgical staff. These benefits have a direct connection with the instrument’s features.
For instance, the device comes with a 3mm atraumatic wire loop tip. Moreover, the tip features horizontal serrations, which prevent the lens from falling into the vitreous humor. Also, the curved profile allows the surgeon to fit smaller lenses shapes.
Besides, the lens loop has a solid, flat handle with a smooth surface. The handle also comes with an ergonomic outline, which enhances gripping and minimizes fatigue.
Lastly, all our Keener-Arlt Lens Loops are available in premium grade stainless steel, ensuring a long-lasting surgical experience to your operating rooms.
Product features
Product features
Made in highest quality, surgical grade stainless steel with satin finish to reduce glare. The instrument can be sterilized and reused.
Materials and care
Materials and care
PRODUCTS
This reprocessing instruction applies to reusable surgical and endoscopic instruments supplied by MEDLENE Medical.
GENERAL
Reusable surgical instruments from MEDLENE Medical can be used by medical professionals for a surgical procedure and can be reused after qualified reprocessing.
The professional user selects the appropriate instruments according to the intended function, the tissue to be manipulated and the anatomical structures.
WARNINGS AND PRECAUTIONS
MEDLENE Medical instruments must be cleaned, disinfected,
and sterilized before first use. Protective caps and transport packaging must be
removed beforehand.
A complete functional check must be carried out before each use. Improper use and overstraining due to twisting / levering can lead to breaks and permanent deformation.
Do not use metal brushes or abrasives, as there is a risk of corrosion due to surface damage. The safe
combination of instruments with each other or of instruments with implants must be checked by the user before clinical use.
Be careful when handling sharp tips and cutting edges - risk of injury.
In case of patients with Creutzfeldt-Jakob disease (CJK), suspected CJK or possible variants of this disease, the applicable national regulations regarding the preparation of instruments must be applied. Never leave instruments in disinfectant solution for too long. Follow the instructions of the respective manufacturer.