Medlene® Bipolar forceps are surgical instruments used in electrosurgery to coagulate tissue, achieving hemostasis by passing a high-frequency electric current between two electrodes. Here are some common specifications for bipolar forceps:
General Specifications:
- Material: Stainless steel or titanium, sometimes with insulated coatings.
- Length: Typically ranges from 7 cm to 24 cm, depending on the surgical application.
- Tip Size: Tips can vary from 0.2 mm to 2.0 mm in diameter.
- Tip Shape: Various shapes, including straight, curved, angled, and bayonet, to accommodate different surgical needs.
- Insulation: High-quality, heat-resistant insulation materials to prevent unintended tissue damage.
- Handle Type: Various designs, including flat, round, and ergonomic handles for better grip and control.
- Connector Type: Compatible with various electrosurgical units (ESUs), typically with standard 2-pin or 3-pin connectors.
- Sterilization: Autoclavable or single-use, depending on the design and manufacturer specifications.
Electrical Specifications:
- Voltage Range: Suitable for use with ESUs that provide a voltage range from 100V to 300V.
- Frequency: Operates at high frequencies, typically in the range of 300 kHz to 1 MHz.
- Current Type: Alternating current (AC), specifically designed for coagulation purposes.
- Power Settings: Adjustable power settings depending on the surgical requirement, often controlled by the ESU.
Product features
Product features
Made in highest quality, surgical grade stainless steel with satin finish to reduce glare. The instrument can be sterilized and reused.
Materials and care
Materials and care
PRODUCTS
This reprocessing instruction applies to reusable surgical and endoscopic instruments supplied by MEDLENE Medical.
GENERAL
Reusable surgical instruments from MEDLENE Medical can be used by medical professionals for a surgical procedure and can be reused after qualified reprocessing.
The professional user selects the appropriate instruments according to the intended function, the tissue to be manipulated and the anatomical structures.
WARNINGS AND PRECAUTIONS
MEDLENE Medical instruments must be cleaned, disinfected,
and sterilized before first use. Protective caps and transport packaging must be
removed beforehand.
A complete functional check must be carried out before each use. Improper use and overstraining due to twisting / levering can lead to breaks and permanent deformation.
Do not use metal brushes or abrasives, as there is a risk of corrosion due to surface damage. The safe
combination of instruments with each other or of instruments with implants must be checked by the user before clinical use.
Be careful when handling sharp tips and cutting edges - risk of injury.
In case of patients with Creutzfeldt-Jakob disease (CJK), suspected CJK or possible variants of this disease, the applicable national regulations regarding the preparation of instruments must be applied. Never leave instruments in disinfectant solution for too long. Follow the instructions of the respective manufacturer.