ENDOCLIP II ML 10 APPLI
ENDOCLIP II ML 10 APPLI
The ENDOCLIP II ML 10 APPLI is a precision endoscopic clipping instrument designed for advanced surgical applications. This multi-load applicator delivers reliable hemostasis and tissue approximation during minimally invasive procedures. Featuring a 10-application capacity, it reduces the need for frequent instrument exchanges, enhancing procedural efficiency. The ML (multi-load) design ensures consistent clip deployment with optimal jaw alignment and secure closure. Engineered for compatibility with standard endoscopic channels, this instrument provides surgeons with dependable performance for gastrointestinal interventions. The ergonomic handle design facilitates controlled manipulation, while the durable construction withstands repeated sterilization cycles. Ideal for managing bleeding vessels, securing tissue flaps, and performing precise ligation in challenging anatomical spaces. Trust ENDOCLIP II ML for professional-grade results in endoscopic surgery.
The Endo Clip II clip applier contains 20 mL titanium clips. The applier is designed for introduction and use through all appropriately sized trocar sleeves or larger sized trocar sleeves with the use of an appropriate converter. The overall length of the shaft is approximately 29 cm (11 in.).
Product features
Product features
Made in highest quality, surgical grade stainless steel with satin finish to reduce glare. The instrument can be sterilized and reused.
Materials and care
Materials and care
PRODUCTS
This reprocessing instruction applies to reusable surgical and endoscopic instruments supplied by MEDLENE Medical.
GENERAL
Reusable surgical instruments from MEDLENE Medical can be used by medical professionals for a surgical procedure and can be reused after qualified reprocessing.
The professional user selects the appropriate instruments according to the intended function, the tissue to be manipulated and the anatomical structures.
WARNINGS AND PRECAUTIONS
MEDLENE Medical instruments must be cleaned, disinfected,
and sterilized before first use. Protective caps and transport packaging must be
removed beforehand.
A complete functional check must be carried out before each use. Improper use and overstraining due to twisting / levering can lead to breaks and permanent deformation.
Do not use metal brushes or abrasives, as there is a risk of corrosion due to surface damage. The safe
combination of instruments with each other or of instruments with implants must be checked by the user before clinical use.
Be careful when handling sharp tips and cutting edges - risk of injury.
In case of patients with Creutzfeldt-Jakob disease (CJK), suspected CJK or possible variants of this disease, the applicable national regulations regarding the preparation of instruments must be applied. Never leave instruments in disinfectant solution for too long. Follow the instructions of the respective manufacturer.
Share