In a healthcare landscape where obesity rates soar and bedside ultrasound becomes indispensable, clinicians face a critical demand: uncompromised performance coupled with portability. Enter ACUSON Juniper – the solution for those who demand more.
This advanced ultrasound system boasts unparalleled imaging capabilities while maintaining a lightweight, portable design. With the ability to scan on battery and a small footprint, ACUSON Juniper ensures clinical excellence across diverse specialties, offering a seamless blend of performance and mobility.
Width 50.8 cm (1.6 ft )
Height: 122.5 to 163.4 cm (4.02 to 5.4 ft)
Depth: 65.4 cm (2.14 ft )
Weight: 76 kg (167.5 lbs)
Monitor: 59.9 cm (23.6 in) full HD 1080p, flat panel liquid crystal display (LCD) with LED back-lighting
Touch screen: 37.8 cm (13.3 in) LCD touch panel
Scan on battery time Up to 75 minutes
Transducer ports Supports five active transducer ports.
Product features
Product features
Made in highest quality, surgical grade stainless steel with satin finish to reduce glare. The instrument can be sterilized and reused.
Materials and care
Materials and care
PRODUCTS
This reprocessing instruction applies to reusable surgical and endoscopic instruments supplied by MEDLENE Medical.
GENERAL
Reusable surgical instruments from MEDLENE Medical can be used by medical professionals for a surgical procedure and can be reused after qualified reprocessing.
The professional user selects the appropriate instruments according to the intended function, the tissue to be manipulated and the anatomical structures.
WARNINGS AND PRECAUTIONS
MEDLENE Medical instruments must be cleaned, disinfected,
and sterilized before first use. Protective caps and transport packaging must be
removed beforehand.
A complete functional check must be carried out before each use. Improper use and overstraining due to twisting / levering can lead to breaks and permanent deformation.
Do not use metal brushes or abrasives, as there is a risk of corrosion due to surface damage. The safe
combination of instruments with each other or of instruments with implants must be checked by the user before clinical use.
Be careful when handling sharp tips and cutting edges - risk of injury.
In case of patients with Creutzfeldt-Jakob disease (CJK), suspected CJK or possible variants of this disease, the applicable national regulations regarding the preparation of instruments must be applied. Never leave instruments in disinfectant solution for too long. Follow the instructions of the respective manufacturer.